Mounting Angle Fasteners Sleeve: #10 bolts or screws, 3/16" (3) steel rivets or 1/2" (13) long welds. The TS150 must be installed at the factory and cannot be added in the field. Greaves Rd. ©Ruskin 2002 FRAME QTY. cheng@jci. 125" (3. Ruskin CFD model ceiling fire dampers provide the appropriate protection needed for openings in fire rated ceilings. g. angles together at corners of dampers. Stainless Steel V-Groove Blades. Unlike conventional mounting angles that can-not be fastened together in the corners and ship separately from the dampers, the FAST and PFMA are: • One piece angles (fastened together in the corners)- Single section dampers ordered with either 12” (305), 14” (356) or 16” (406) long sleeve; the IBD20, 40, 60, 230, 430 and 630 models may be substituted. dampers. Specifier select damper shall have SPC field-adjustable static-pressure control to maintain pressures in ranges from . ft. per sq. The PVC12 damper is a corrosion-resistant and low-maintenance device that can regulate air flow in ducts or pipes. @ 4" w. Masonry/Wall or Floor: #10 self-tapping concrete screws. Designed to protect life and property, Ruskin® manufactures a complete line of UL classified dampers. Ruskin August 2020 Page4 CONSTRUCTION & DIMENSIONAL INFORMATION Multi-section Dampers Dampers over the maximum single section size will require multiple damper sections, typically built in equal sizes. • UL555S requires that all combination fire smoke dampers have factory mounted actuators in order to bear the UL label. Specifying and installing low-leakage dampers (Class 1 preferred, Class 2 at a minimum by code) helps ensure that the building HVAC system is operating at its most energy-efficient level. to. It features: Static Ceiling Fire (Radiation) Damper Use in Fire Resistive Floor/Ceiling or Roof/Ceiling Assemblies 165 ֯ F or 212 ֯ F Fusible Link Blade Insulation CSFM 3225-0245:0101. With the variety of models, sizes, and paint finishes available, Ruskin Louvers can add unusual and appealing features to exterior and interior elevation. g. 3 (damper installed with duct upstream and downstream). The TDP05K is capable of measuring a velocity range from Oto 5,000 FPM and displaying the flow and temperature. Masonry/Wall or Floor: #10 self-tapping concrete screws. The industrial grade backdraft dampers offer rugged construction and heavy gage materials to withstand the high velocities and back. 2. Each has added features that enable them to meet all high temperature, high pressure. (Consult Ruskin for detailed CSI MasterFormat Specification. ,Application The No. Consult Ruskin or your Ruskin repre-sentative when damper is to be applied in conditions exceeding recommended maximums. Mounting Angle Fasteners Sleeve: #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) lo ng welds. FILES (0) Share this page: Trusted for decades, Ruskin V-Groove blade dampers were designed to extend a lower cost solution for standard duty (medium or low pressure) applications. cealed in the frame. Non-stick, noncorrosive bearings that assure. The integral frame and unique “cinch plate” design provides a low cost, high performing damper. 248 Kpa) tested per AMCA 500. Marketing Literature; Case Studies;. Specifier Select Option Dampers shall be equipped with factory installed damper position indication switch package. g. • Airfoil blade design for low pressure drop and reduced noise generation. The Quick Product Selection Reference Guide assists in selecting the appropriate Ruskin® Product for your application. For best pressure drop and sound perfor-mance at higher velocities, consider an airfoil blade damper, such as Ruskin model CD50-CE. Mounting Angle Fasteners To sleeve #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) long welds. From our humble beginnings with a handful of employees building fire dampers, Ruskin has grown into the largest and most innovative manufacturer of air control solutions with 29 production and office locations worldwide. Determine area factor for damper by entering the Area Factor Table through duct width and height. Leading the industry with innovative designs, Ruskin aluminum airfoil blade dampers are constructed utilizing high yield 6063T6 extruded aluminum frame and blades. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowIBD2G, IBD2SSG (Static) and DIBD2G, DIBD2SSG (Dynamic) curtain type fire dampers for grille installation may be installed vertically in walls or horizontally in floors with fire resistance ratings of less than 3 hours. g. g. GRANDVIEW, Mo. (2) 1/4-20 Nuts 2. The damper/actuator assembly is exposed to elevated temperatures for 30 minutes and then immediately cycled three times. Reinforcing plates are not required for assemblies consist-ing of two dampers attached end-to-end or three dampers attached side-to-side as depicted in figure 3. 4) steel. Actuators are designed to operate reliably in smoke control systems requiring Underwriter’s Laboratories, Inc. Counterbalance weights that can be set to relieve air pressure differentials less than . Opposed blade dampers must be operated from a power blade on the. Opposed blade dampers must be operated from a power blade on the. Built from strong materials and designed on state-of-the-art. The ELBD375E Automatic Exhaust Dual Combination aluminum louver combines a drainable blade louver and an exhaust backdraft damper in a nominal 6” frame depth. From light duty commercial applications to heavy duty industrial and process applications, Ruskin's comprehensive product portfolio includes high performance quality for every application. DIBD2GA fire dampers are idealAMCA Publication 500. R8039)<o:p></o:p> Static Ceiling Fire (Radiation) Damper Use in Fire Resistive Floor/Ceiling or Roof/Ceiling Assemblies 165 ֯ F or 212 ֯ F Fusible Link Curtain type. 2) wall thickness with 12 gage (2. To meet the diversity of fire and smoke protection requirements,. Greaves Road Grandview MO 64030 Phone: 816-761-7476 ruskin@ruskin. It features: Airfoil blades, which have greater strength, less static pressure, superior sealing ability, superior fire protection ability and produce less noise. Material thickness shall be equivalent to Ruskin model CDR25 or CDO25 standard construction. It features: Vertical blades. Linkage is concealed in the frame out of the airstream for low maintenance and reduced. Specifying and installing low-leakage dampers (Class 1 preferred, Class 2 at a minimum by code) helps ensure that the building HVAC system is operating at its most energy-efficient level. Our plant in Thailand is well-equipped to manufacture next-generation products. Ruskin fire dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. 3 (damper installed with duct upstream and downstream). Unless specifically ordered otherwise, when looking at the concealed linkage side of the damper and the bottom blade Louver and Architectural. Ruskin manufactures a complete line of louver models available for both standard and special needs, such as high-volume airflow, wind driven rain, special architectural shapes, sight proof. Home; PRODUCTS Air Control and Backdraft Dampers Ceiling Radiation Dampers. Actuator can be field converted to power open and spring or "fail" closed. Specifier select damper shall have SPC field-adjustable static-pressure control to maintain pressures in ranges from . appliCaTion CFD7 is the first Ceiling Radiation Damper to be UL listed for steel joist assemblies (L524). CD60SS SUGGESTED SPECIFICATION Furnish and install, at locations shown on plans, or in accordance with schedules AMCA certified, low leakage airfoil control dampers meeting the following minimum construction standards. Our line of outside air dampers are available in 0% - 35% range or 0% - 100% range, and all are easy to install with factory-provided plugs. When ordered, as an option, the DTS will beThe DFD60 is a UL555 classified, 1 1/2 hour rated, multiblade fire damper. the damper/sleeve. It features a galvanized steel frame, single skin blades, and a variety of actuator options. Refer to the UL approved installation instructions for specific requirements. While providing fresh air intake and exhaust, Ruskin Louvers can also provide architectural style to building design. 25" w. Ruskin model CD60 offers HVAC design engineers an ultra-low leak high performance damper which provides: • Energy savings for building owners • Low noise generation and lowest pressure drop • Low maintenance Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below Insulating Control Dampers. Airfoil blades, which have greater strength, less static pressure, superior sealing. 2. Ruskin fire/smoke dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. Standard features vary by model to make application selection straightforward. They are designed to be installed inside duct work rather than flange mounted. When joining multiple damper assemblies or fastening the damper to the sleeve, dampers shall be fastened with 1/4-20 (M6) bolts, number 10 (M5) screws, or 1/2" (13) long welds stag-gered intermittently on both sides. Louvers & Architectural. The switch package shall include two position indication switches linked directly to the damper blade to provide full open and full closed damper. We are the leading manufacturer of air and sound. Rectangular Silencers. be-csd-thailand@jci. Spec FSDGA-216/Replaces FSDGA-1115 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. The CFD8 is UL555C Classified Ceiling Fire (Radiation) Damper (CABS. Standard, 1 1/2 and 3 hr. The Ruskin backdraft damper model CBDR92 is designed to prevent backflow in high velocity HVAC and industrial process systems. It features: Corrosion resistant backdraft protection from its stainless steel construction. Dynamic fire dampers shall be Ruskin model DFD60-3. Aluminum Airfoil Blades. Website: AUTHORITY IN AIR CONTROL Phone: (816) 761-7476. com. FSD35 FSD36 FSD60 CDO25 CDO25 CD35 CD36 CD50 CD60. Industrial Multi-Blade Control Damper. ft. • Kansas City, MO 64030 • (816) 761-7476 • FAX (816) 765-8955. Backdraft blades are . Unless specifically ordered otherwise, when looking at the concealed linkage side of the damper and the bottom blade Ruskin FDR25 is a true round fire damper designed for use in fire rated walls and floors and is the perfect choice when using round duct. Unequal section sizes. 7447 Toll Free: 800. Blades have an integral structural reinforcing tube running full length of each blade. Dampers above 40" (1016) – 10 gage with retainer ring. 761. Every damper is built with performance in mind and tested per AMCA standards in Ruskin's Laboratory. Ruskin Green Products. Built from strong materials and designed on state-of-the-art equipment, Ruskin Industrial Control Dampers are perfect for demanding conditions. Ruskin Company certifies that the SD50 shown hereon is licensed to bear the AMCA Seal. Caution: Volume Adjust hangs below a rectangular damper 1 1/8”® Furnish and install at locations shown on plans or in accordance with schedules, bubble tight isolation dampers meeting the following specifications. To determine the pressure drop: 1. The FSD60 can be installed in horizontal or vertical applications and has low leakage and pressure drop ratings. Ruskin round and oval solutions are perfect for applications utilizing spiral duct, or transitioning from rectangular to round. Testing has proved that the CD40x2 insulated more efficiently than conventionally insulated blades. pivot pins. g. Damper shall be tested and licensed in accordance with AMCA 511 for Air Performance and Air Leakage. (2) ‘S. Consult Ruskin or your Ruskin representative when damper is to be applied in conditions exceeding rec - ommended maximums. Use the details shown on pages 2 and 3 to determine how Ruskin multiple blade dampers with standard construction and sizes up to 240" wide by 144" high will be assembled and manufactured. dampers are for use in dynamic (fans on) or static (fans off) sys-tems. Horizontal Installation – 6"w x 6"h (152 x 152). Some of the approved ceiling designs are L501,. Face and by-pass arrangement. Air Measuring Station with Integral Damper: 15" 300-5000: Transducer (LCD Display Optional) Optional: 3%: W 6" H 6" W 60" H 72" Velocity Pressure:. Ruskin fire/smoke dampers. for dampers up to 17. They also offer a new coupler option that joins two damper sections without a jackshaft allowing an actuator to be mounted on side of frame to provide a narrow profile when space is limited. Commercial dampers provide low-pressure openings with excellent pressure-drop performance. Ruskin's Commercial Control Dampers provide superior air control, high performance, and sustainable energy efficiency. Ruskin CD30AF1/CD30AF2 con-trol dampers. Ruskin ® 00 Dr. g. It features: Accurate airflow and isolation at extreme elevated temperatures. Horizontal dampers installed in walls and floors shall have extended dynamic closure and operational ratings of 4000 fpm (20. ©Ruskin February2016 Model FSD60GA and FSD36GA series meet the requirements for combination fire and. Ruskin UL listed solutions are available. Damper Dia. The industrial grade backdraft dampers offer rugged construction and heavy gage materials to withstand the high velocities and back. - Damper/sleeve assembly furnished actual size to inside of sleeve. 761. Availability: Get a Quote. 3 (damper installed with duct upstream and downstream). g. The CD40x2 has an 8" frame and aluminum construction. w/ damper - - ELF6375DXD Horizontal drainable blade Wind-borne debris regions (non-essential buildings), HVHZ, areas with rain management system ±148 6” N/A TDI Water, Air 540 & 550 w/ damper ELC6375DXD Horizontal drainable combination louver/ damper Hurricane-prone regions, HVHZ, areas with rain management system, applications. (1 kPa) static pressure and shall be tested and rated to close with airflow in either direction. Ruskin Brands and Locations. Dampers For More Information: Manufacturer's Site. Auto-Balancing. Single Blades. It features: Airfoil blades, which have greater strength, produce less sound, greater sealing ability, and static pressure loss. CD60 | Galv. When Ruskin’s Fire/Smoke Dampers are supplied with a factory installed damper sleeve, the sealed. STATIC PRESSURE IN IN. Ruskin model CD50IF offers HVAC design engineers an ultra-low leak high performance damper which provides: AMCA Class 1A leakage for energy savings Integral 1 ½” flange (front or rear) Mechanically fastened blade edge seals for longevity Shake proof linkage for low maintenance This catalog offers Damper customers an easy to use buying guide for miscellaneous Ruskin Damper parts. Ruskin manufactures an extensive line of UL rated and listed dampers to protect life and mitigate property loss during a life safety event. FILES (0) Share this page: Catalog. Each has added features that enable them to meet all high temperature, high pressure airflow. Masonry Wall or Floor: #10 s elf-tapping concrete screws Wood/Steel Stud Wall: #10 screws. Multiple section damper assemblies may require brac - ing to support the weight of the assembly and to hold against sys - tem pressure. damper section width as indicated. Fewer parts, fasteners, and assembly processes ensure years of sustainable performance in heavy duty applications. 5 21w ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. 500. back pressure depending on damper size. Ruskin fire/smoke dampers. 3900 Dr. Face and by-pass. Torque applied holding damper closed at 10 in. Consult Ruskin on your Ruskin representative when a damper is to be applied in conditions exceeding recommend-ed maximums. It can be equipped with the industry's shortest sleeve and is ideally suited for shaft wall applications. Maximum 8" static pressure UL approval for dual directional airflow Failsafe design, which enables the damper to automatically assume the desired. Data for one size damper is not acceptable. Dampers shall be in all respects equivalent to Ruskin Model CDRS25. 7 %âãÏÓ 69 0 obj > endobj xref 69 77 0000000016 00000 n 0000002434 00000 n 0000002561 00000 n 0000004375 00000 n 0000004685 00000 n 0000005201 00000 n 0000005701 00000 n 0000006313 00000 n 0000006746 00000 n 0000007307 00000 n 0000007930 00000 n 0000007966 00000 n 0000008506 00000 n 0000008619 00000 n. It is Leakage Class I classified and features: UL555S Class I. g. Unless specifically ordered otherwise, when looking at the concealed linkage side of the damper and the bottom blade turnsA. Steel construction with aluminum paint finish. Ruskin Control Dampers and Backdraft Dampers Get the air where you want it — when you want it! 3 CD60 Ultra Low Leakage Damper The CD60 damper is a “true” airfoil blade damper designed for medium to high velocity and. COMMERCIAL CONTROL, MANUAL, AND. a. From our humble beginnings with a handful of employees building fire dampers, Ruskin has grown into the largest and most innovative manufacturer of air control solutions with 29 production and office locations worldwide. • Kansas City, MO 64030 • (816) 761-7476 vFBD35 IRIS BALANCINg DAMpER Ruskin IRIS Balancing Damper model VFBD35 is an excellent solu -For other damper sizes refer to Air Performance Data For All Smoke Dampers spec sheet. Mounting Angle Fasteners Sleeve: #10 bo lts or screws, 3/16" (5) steel rivets or 1/2" (13) long welds. A. Damper shall be equivalent to Ruskin model ARD25. The BD6 backdraft damper is ideally suited to heavy duty applications and is AMCA certified for Leakage and Performance. Ruskin CD60DC is rated for airflow in either direction, but Ruskin defines the “front” of the damper as the opposite side of the jackshaft and the “rear” as the jackshaft side. Ruskin’s smoke dampers are UL555S labeled with either electric or pneumatic actuators mounted internal (in air stream) or external (out of air stream). Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowShare this page: Combination Fire/Smoke dampers are low leak damper and actuator assemblies that have passed the UL555 and UL555S test requirements. Relief doors open automatically to prevent ductwork from imploding or exploding due to differential pressure. It locks together without bolts, screws, or rivets that could shake loose. Determine the airflow in CFM. For some applications, it is essential that thermal conductivity be kept at a minimum. Ruskin Literature. Ruskin - Dampers Louvers (816) 761-7476 Subject: The FSD35 is a combination fire and smoke damper designed with triple V-groove blades and controlled closure technology that provides point-of-origin fire containment and operational flexibility in static and dynamic smoke management systems. Industrial Fiberglass Louvers. This folder features all of the latest literature that Ruskin has produced, available in. The. Dampers shall be in all respects equivalent to Ruskin model CBD2. Find the conversion velocity (CV) by multiplying the selected size damper's area factor by the flow rate in CFM: CV = Area Factor x CFM 3. static pressure. II. Round Control Dampers. Ruskin ® Terms and Conditions for more information. II. of damper with minimum of 20 in. The maximum opening. Wood/Steel Stud Wall: #10 screws b. MODEL 914 SUGGESTED SPECIFICATION Suggested specification for Model 914 Ruskin Swartwout Fiber-glass Series round dampers (revision 6394). a. Galvanized Steel Airfoil Blades. , with order). Ruskin's all aluminum damper for medium and low pressure commercial HVAC systems offers low leakage with a stan-dard, commercial built damper. Product offerings include Air Control & Distribution products,. Actuators & Damper Accessories Ruskin provides a wide variety of actuators and other accessories to customize our dampers in order to meet your needs. Specifier Select Option Dampers shall be equipped with factory installed damper. This damper is fitted with a counterweight assembly that can be field adjusted and calibrated to meet the specific airflow requirements of your unique system. Pressure Relief Doors. Deflections in other damper widths (less than 48" [1219]) at Smoke dampers are UL555S tested and labeled, low leak damper and actuator assemblies constructed to restrict the spread of smoke in HVAC systems that are designed to be automatically shut down in the event of a fire, or opened to control the movement of smoke within a building when the HVAC system is part of an engineered smoke control system. The damper is rated for5 82w ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. The FSDR60 is a "true round" Class 1 leakage rated combination fire and smoke damper designed for use in metal, wood or concrete fire and smoke rated partitions and concrete floors. Press and Drag to Scroll. Dynamic fire dampers shall be Ruskin multiple model DFD35. Ceiling Fire Dampers UL Classified Radiation Dampers for Wood Joist Construction The CFD7 is a UL Classified Ceiling Fire Damper that is UL approved for installation in ceilings constructed from wood joists. These designs are also similar to the fire resistance rated ceiling construction described in the International Building Code. Ruskin manufactures a complete line of louver models available for both standard and special needs, such as high-volume airflow, wind driven rain, special architectural shapes, sight proof. The uick Product Selection Reference Guide assists in selecting the appropriate Ruskin® Product for your application. Shop custom order Ruskin Dampers and Airflow products for your HVAC needs. Ruskin Literature. 11-17-20. Ceiling fire dampers, also known as "Radiation" dampers, are designed and tested to limit the radiant heat transfer through an air inlet/outlet opening in the ceiling membrane of a fire resistance rated floor/ceiling or. 3 m/s) and 8” w. Various relief air control settings are created by simple. • Sealing durability in. Ruskin® was founded in the Ruskin Heights area of Kansas City in 1958. lbs. Share this page: Guillotine "fire damper" fabricated from a fire resistant panel used in the construction of 3 hour UL tested and labeled sliding fire doors. From light operations to heavy-duty industrial applications, Ruskin provides the perfect backdraft damper. The FSDR60 is the ideal choice when round duct is used on a project. g. Control dampers shall be produced in an ISO9001 certified factory. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy Literature; Videos; Webinars; Revit® Models; Architectural Gallery; FAQs. All data has been. Ruskin model CD50 offers HVAC design engineers an ultra-low leak high performance damper which provides; • Energy savings for building owners • Low noise generation and lowest pressure drop • Low maintenance. Refer to the UL approved installation instructions for specific requirements. The Ruskin Company’s (hereinafter “Ruskin”) content, functionality and product information provided in this data file, including Ruskin design and dimensions (collectively referred to herein as “Ruskin’s Information”) are offered solely to you as a convenience and are for your information only. Combination Fire/Smoke Damper UL555 and UL555S Leakage Class 1 Classified The FSDR60 is a true round, Class 1 leakage rated combination fire/smoke damper designed for use in metal, wood, or concrete fire and smoke rated partitions and. Frame shall be 16 ga. Ruskin's complete line of zone control products was developed to meet an increasing demand for zone specific products combined with individual controls. Ruskin Construction has been intent on developing our marine capacity for two decades with the strategic acquisition of various marine construction companies in. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowRuskin continues to provide the industry with the most UL approved field installation solutions for fire and fire/smoke dampers. 075 lb/cu ft air. The FSD60 is a combination fire and smoke damper that meets UL555 and UL555S standards. 1. (2 kPa). (Dampers with V-Groove blades are structurally designed for velocities to 2000 FPM and above. Access Doors. Leakage information based on pressure differential of 1" w. Complete with 24V modulating actuator and field wired wall mounted, the thermostat gives individual control to office spaces with single or multiple branch ducting. Ruskin Fire, Smoke, and combination fire/smoke dampers meet the strict requirements established by the International Fire Code (IFC) and the International Building Code (IBC). As an option, qualification for use in Nuclear. All calculations are with external mounted actuators and accessories. See “Smoke Damper Multiple Section Detail” spec sheet for details. Ruskin recommends appropriate bracing to support the damper horizontally at least once for every 8 'of. angles together at corners of dampers. 247. It also features: Frame corners that are internally braced to reduce racking. A change anywhere is a change everywhere, instantly!2. Specifier Select Options. The industrial grade backdraft dampers offer rugged construction and heavy gage materials to withstand the high velocities and back. Our History. 1. FSD36 126"x 96"or 72"x 122" 4"w. The TS150 allows the dampers to be reopened after the initial closure for dynamic smoke control. RectangulaR DampeRs CD40, CD50, CD60 SerieS DeSCripTiOn The ruskin CD40, CD50, CD60 parallel and opposed-blade HVAC control dampers are custom made-to-order. L586) Ceiling fire dampers maintain the integrity of fire resistive ceiling assemblies constructed from wood True Round Grille or through ceiling membrane penetrationRuskin February 222 Page 1 FDR25 Galvanized Steel True Round Fire Damper 1 1/2 Hour UL555 Rating for use in Dynamic & Static Systems Ruskin FDR25 is a true round fire damper designed for use in fire rated walls and floors in either Static or Dynamic systems. It features: 750 degree F standard temperature rating! A variety of applications in air and material volume control systems. Enter the Pressure Drop Chart at the determined area factor. OPTIONS True Round Fire Damper See model FDR25. MODEL CBDR912 FIBERGLASS ROUND BACKDRAFT DAMPER 3900 Dr. It also features: Frame corners that are internally braced to reduce racking. Mounting Angle Fasteners To sleeve #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) long welds. 7476 Fax: 816. These louvers are popular for warehouse applications and other structures in which you want to close the airflow without the use of a damper. Learn about the features, specifications and benefits of different series of Ruskin products, such as TDP05K, CD60, CD50, CD40, CDRS15, CDRS25, TED40 and TED50. Multiple velocity and temperature points on one or more probes installed in the duct or plenum are averaged to arrive at air measurements. Excellent weather protection when installed in. For best pressure drop and sound perfor-mance at higher velocities, consider an airfoil blade damper, such as Ruskin model CD60. Masonry/Wall or Floor: #10 self-tapping concrete screws. 3. Zone Control Systems. for dampers up to 6 sq. GENERAL INSTALLATION NOTES 1. Dampers can be constructed of galvanized, stainless, or. UL approval for dual directional airflow. Greaves Rd. Model ZCRD25 can also be supplied with Ruskin Cable drive systems. Minimum damper size for BD6 with SPC is 12" x 12" (305 x 305). The SDRS25 is a UL555S Classified round smoke damper. Dampers shall be in all respects equivalent to Ruskin Model CDRS25. 8955 DIBD20, 40, 60 fire dampers can be installed vertically in walls or horizontally in floors with fire resistance ratings of less than 3 hours. g. Damper locks together without bolts, screws, or. max Extremely tight shut-off. Ruskin fire/smoke dampers. The Diffuser Radiation Shield, which allows any manufacturer's lay-in style steel ceiling diffuser (subject to gage and dimension limitations) to be installed in UL Classified F/C or R/C assembly with Fire. Pressure drop and free area may vary. at corners of dampers. The CFD7T-SR is a UL Classified Ceiling Fire Damper listed for installation in wood truss floor/ceiling and roof/ceiling designs L528, L546, L558, L574, L585, L586, L592, P533, P545, P548, P572, and H502. Dampers shall be in all respects equivalent to Ruskin model IL35. Damper Width “A” Dimension in inches ()The CDRI95 Round Isolation Damper is designed for round duct work capable of 20" w. See “Combination Fire Smoke Damper Multiple Section Detail” spec Ruskin February 222 Page 1 FDR25SS Stainless Steel True Round Fire Damper 1 1/2 Hour UL555 Ratings for use in Dynamic & Static Systems Ruskin FDR25SS is a stainless steel true round fire damper designed for use in fire rated walls and floors in either Static or Dynamic systems. With Seals Dampers 40" (1016) and under – 2 pieces of 18 gage steel. The integral frame and unique “cinch plate” design provides a low cost, high performing damper. Static pressure and CFM are corrected to . Get free shipping on orders over $999!%PDF-1. Dampers shall be Ruskin model FSDR25. The CD80AF2 Industrial Control damper has an 8" frame. (25) sp. Commercial Dampers; Diffusers; Economizers; Energy Recovery Ventilators; Industrial Dampers; Life Safety Dampers; Louvers & Architectural; Pressure Relief Doors; Noise. The Quick Product Selection Reference Guide assists in selecting the appropriate Ruskin® Product for your application. Ruskin triple V blade fire/smoke dampers do meet the 3000 fpm, 4" w. It is rated as a 1-1/2 hour fire damper and a Leakage Class II Smoke damper. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowSun Control Sunshades. Use "Mount With Arrow Up" label as a guide for proper damper orientation. The TDPOSK is a highly accurate thermal dispersion airflow and temperature measuring probe. The webpage provides the specifications and features of the Ruskin® CD80AF1 and CD80AF2 industrial control dampers, which are designed for heavy duty applications and high temperature environments. These same finishes provide extended weathering resistance similar to adjacent building surfaces. yeoching. The IBDT carries a 1 1/2 hour UL fire damper label and is classified as a static damper for use in HVAC systems that shut down during a fire. While is it true that triple V blade dampers and modified single skin type have been qual-ified to 3000 - 4000 fpm or more at 4" w. A complete line of damper products for fire and smoke control in life safety systems and for airflow control in commercial HVAC and industrial systems. c. The damper ships with a factory mounted and commissioned 24 VAC, spring return actuator set to power closed and spring or "fail" open. Please refer to the table of contents below to determine where to find complete details on products, pricing, and ordering. the application of firestopping caulk in the annular space surrounding a fire or fire/smoke damper <b>is not. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below on dampers with v-groove blades, we recommend sizing dampers for 1,500 fpm. Damper – Ruskin fire or fire/leakage rated damper in minimum 20 gage (1. ft. The damper shall be rated for dynamic closure at 2000 fpm (10. Conservative ratings are pre-sented intentionally in an effort to avoid misapplication. Must be installed in the factory. , Ltd. g. Combination Fire/Smoke dampers are low leak damper and actuator assemblies that have passed the UL555 and UL555S test requirements. Built from strong materials and designed on state-of-the-art equipment, Ruskin Industrial Control Dampers are perfect for demanding conditions. 16 (per ASTM C1363-2011) Thermal break in blade eliminates any thermal path, reduces condensation Mechanically fastened blade edge seals for longevity Shake proof. g. These designs are also similar to the fire resistance rated ceiling construction described in the International Building Code. All data has been cor- Dampers 18" (457) and under – 12 gage steel (2. V Groove & Single Blades. 5. g. Life Safety » Combination Fire/Smoke Dampers 1. Warranty claims under this Limited Warranty should be referred to: Ruskin 3900 Dr. Dampers can be constructed of galvanized, stainless, or aluminum and are available with a diverse compliment of. g.